Case report of contrast transesophageal echocardiography to confirm extracorporeal membrane oxygenation (ECMO) catheter position in aortic dissection
Introduction
This is the first reported case of using microbubbles to confirm extracorporeal membrane oxygenation (ECMO) catheter position in a patient with aortic dissection. We present the following article in accordance with the CARE reporting checklist (available at http://dx.doi.org/10.21037/jeccm-20-166).
Case presentation
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and with the Helsinki Declaration (as revised in 2013). Informed consent was obtained from the patient and his relatives.
The patient was a 27-year-old man presented to the emergency department for hypotension, chest pain and tearing back pain. He developed refractory cardiac arrest with ventricular fibrillation. Extracorporeal cardiopulmonary resuscitation (ECPR) was set up with a 15-Fr arterial catheter set at the left common femoral artery and a 23-Fr venous catheter set at the left femoral vein. Initial work up for causes of arrest showed widened mediastinum in chest radiograph. In view of unstable hemodynamics and high transport risk, transesophageal Echocardiography was performed at the bedside and revealed type A aortic dissection. To confirm whether the arterial ECMO arterial catheter was perfusing the true lumen, 2 mL of microbubble contrast, Sonovue (Bracco Imaging S.p.A), was injected through the side port of the arterial catheter while imaging the descending aorta with transesophageal echocardiography, with mid-esophageal view at zero degree and imaging probe facing posteriorly. The contrast was filling initially the compressed true lumen and then the false lumen, indicating that the ECMO is preferentially perfusing the true lumen but there was communication between the true and the false lumens. Due to the fast blood flow created by the ECMO circuit, the filling of the false lumen through the communication channels was immediate, in just one second, after the true lumen was filled, and the sequential contrast filling of the true and the false lumens was best appreciated with the cine film viewed in slow motion (Figure 1 and Video 1). Computed tomography subsequently confirmed type A aortic dissection from root to bilateral iliac arteries. The patient was managed by aortic root operation, valve and arch replacement and the ECMO support could be terminated subsequently.
Discussion
This bedside contrast transesophageal echocardiography assessment offered a quick novel means to assess if the arterial ECMO catheter was perfusing the true or the false lumen. We have tried this method in one patient only as ECPR initiated in patients with aortic dissection was not that common. In order to prove the efficacy, this technique should be tried in more patients with ECMO and dissection with various perfusing conditions, like those with arterial ECMO catheter perfusing the false lumen, before it can be recommended.
Acknowledgments
Funding: None.
Footnote
Reporting Checklist: The authors have completed the CARE reporting checklist. Available at http://dx.doi.org/10.21037/jeccm-20-166
Conflicts of Interest: All authors have completed the ICMJE uniform disclosure form (available at http://dx.doi.org/10.21037/jeccm-20-166). The authors have no conflicts of interest to declare.
Ethical Statement: The authors are accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved. All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and with the Helsinki Declaration (as revised in 2013). Informed consent was obtained from the patient and his relatives.
Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0/.
Cite this article as: Au SY, Fong KM, Yung SK, Ng GWY. Case report of contrast transesophageal echocardiography to confirm extracorporeal membrane oxygenation (ECMO) catheter position in aortic dissection. J Emerg Crit Care Med 2021;5:34.